Tuesday, October 21, 2014

How to Generate IEC 61850 IED Models?

IEC 61850-6 (SCL – System Configuration Language) supports the design, engineering and configuration of systems … systems composed of many IEDs (Intelligent Electronic Devices). One key question is: How can I define a model of an IED?

Big vendors like ABB, GE, Siemens, … have their own vendor-specific tools. What’s about third-party tools? Or even freely available tools?

The following tools may be used for free (with some restrictions):

IEDmodeler from RedWind:

IED Modeler is a tool free for use as long as you have an access to the internet and accept their license … The program is free of charge for non-profit purposes including teaching and research at universities, colleges and other educational institutions, research at non-profit research institutions, and personal non-profit purposes.

Click HERE for more information.

ICD Designer from SystemCorp:

The ICD Designer can be used to model IEDs according to Edition 1 and Edition 2 of the core parts of IEC 61850. In addition to modeling IEDs it can be used to bind Models to real applications: bind the “XCBR2.Pos.stVal” to a specific memory location or to a Modbus Coil:

image

The “Pos.stVal” can be bound to a Modbus Slave:

image

This binding allows automatic configuration of the IEC 61850 Stack/API and binding to the corresponding Modbus device at address 321.

Other bindings are supported: DNP3, IEC 60870-5-104, …

The ICD Designer can be used to simplify the application of the SystemCorp IEC 61850 Stack/API.

Click HERE for more information on the ICD Designer. The ICD Designer can – of course – also be used for creating CID Files.

Saturday, October 11, 2014

Does IEC 61850 Add Complexity for Technicians in Power Utilities?

This week I was asked the question in the title during an introduction of IEC 61850 to some 15 utility experts. My response was not just yes or no. Initiated by that question I thought it would be of interest to discuss this issue on the blog.

We have to understand that the expected complexity in power system information exchange has at least the following three crucial aspects:

  1. Complexity of the network infrastructure (independent of protocols defined and used by standards like IEC 60870-5-104, DNP3, IEC 61850, IEC 61400-25, …). The infrastructure used and discussed these days seems to explode! Compared to dial-up-links and and fixed land lines used usually for remote access of something, the application of Switched Ethernet, Ethertype, VPN, VLAN, TCP/IP, UDP/IP, GSM, UMTS, LTE, … requires a good understanding of your needs and the various solutions that could be used.
  2. Complexity of standards (like IEC 60870-5-104, DNP3, IEC 61850, IEC 61400-25, …) that use the above infrastructure.
  3. Complexity of communication software and application interfaces between applications and communication software, and complexity of engineering and configuration tools.

In many cases I have experienced that users do have little understanding what they really need! And may even have lesser knowledge about the various solutions, how to use them for their systems, and to understand how they impact the dynamics of the whole system!

I have talked to many people that have complained about the complexity of protocols … but usually we figured out that the complexity was caused by a bit of everything … and mainly by the fact that people tend to NOT TRUST the chain of solutions from, e.g., a control system application to an API of a front-end, front-end application, protocol API, protocol IEC 60870-5-104, TCP/IP, VPN, GPRS, RTU, interface between RTU and remote application, and remote application.

Here is an example I have experienced recently (with the topology based on GPRS as listed above):

  1. The control system does not trust that the information exchange with the RTU is reliable and available. Therefore the control system sends Pings every 2 seconds.
  2. The front-end application does not trust that the RTU is reliable and available. Therefore the front-end applications issues a 104 control command (toggle bit) every 10 seconds … just to see if the 104 protocol is still alive.
  3. The front-end application does not trust (even it figures out that the RTU is available) that the remote application is really receiving a parameter setting for a function in the remote application. Therefore the remote application copies a received setting value to another 104 information object and sends a spontaneous message with the just received setting value.
  4. The protocol IEC 60870-5-104 exchanges flow control messages to acknowledge the received messages (in both directions).
  5. TCP uses flow control messages and keep alive messages …

So, what do you think about such a bunch of deep mistrusts? Do you think that such a system would work properly and reliable?

I guess that there are many huge GAPS: in the understanding of the NEEDs, the various links in the chain like the dynamics of a system using, e.g., GPRS, … the APIs, the applications …

I recommended to the audience that there is a crucial need for: MORE EDUCATION !! 

A screw driver is not sufficient for future power delivery systems. And: Ignoring IEC 61850 is not sufficient to get the job done! IEC 61850 solutions can be very easy for simple needs.

You can experience it – if you want! Let me know!

Just Published: Resilience and Security Recommendations for Power Systems with Distributed Energy Resources (DER)

IEC TC 57 just published a Proposal of an IEC Technical Report (57/1514/DC) on

Resilience and Security Recommendations for Power Systems with Distributed Energy Resources (DER) Cyber-Physical Systems (proposed IEC TR 62351-12)

Comments are expected by 2015-01-16

While recognizing that the resilience of the power system to anomalous conditions has many components and extends far beyond the impacts of DER systems, the focus of this document is the role of DER systems in grid Resilience, including:

  • DER System Resilience: The cyber security and engineering strategies for designing and installing DER systems to provide DER resilience to anomalous power system events and cyber attacks.
  • Grid Resilience for Planning with Significant Numbers of DER Interconnections: The cyber security and engineering strategies for promoting grid resilience by studying the impact of and planning for interconnecting DER systems with the grid to promote grid resilience.
  • Grid Resilience for Operations with Significant Capacity of DER Generation and Storage: The cyber security and engineering strategies for operating the grid with significantly large numbers and capacities of DER systems that can impact grid reliability and security.

It is highly recommended to review this document during the draft stage. It is more convenient to revise the draft now … than waiting until the document has been published as a final document. The content is very important for the future of power systems.

Contact your national committee for more information.

Just Published: Draft IEC 61850-90-10 Objects for Scheduling

IEC has just published the following document (57/1510/DC):

Draft IEC TR 61850-90-10 – Communication networks and systems for power utility automation – Part 90-10: IEC 61850 objects for scheduling

Comments are expected by 2014-12-05.

Schedules configure a specific behavior during configured time intervals. A schedule consists of a series of entries with a setting for the value of a set point, the selection of a particular mode or the value of a parameter for a mode.

Schedules can be used to allow even more autonomous control of the behavior of DER equipment. They may be sent ahead of time, and then activated at the appropriate time, e.g., for applications like:

  • direct values (e.g. setpoints for P/Q/cosphi)
  • constraints (e.g. do not exceed the maximum value of P/Q/cosphi at a certain time)
  • pricing information (act on constraints)
  • modes (e.g. Volt-VAr curves)
  • parameters of modes
  • predictions or forecasts

This part defines two additional Logical Nodes (schedule and schedule controller):

image

LN FSCH - defining schedules (23 Data Objects)

LN FSCC – schedule controller (3 Data Objects)

It is highly recommended to review this document during the draft stage. It is more convenient to revise the draft now … than waiting until the document has been published as a final document.

Contact your national committee for a copy.

Friday, October 10, 2014

HMS offers IEC 60870-5-104 and IEC 61850 Gateway

HMS is a well known company in the world of communication solutions for any kind of Automation in factories, chemical plants, ... HMS is active in more than 50 countries, with some 350 employees, with the head office in Halmstad (Sweden).

HMS has understood the importance of the standards IEC 60870-5-104 and IEC 61850: Their latest offering are new Gateways under the Product line LABLINE SG. The new products are applicable in any Smart Grid application like Photo Voltaic, Wind Power, CHP, Backup Power, Metering, Power Quality, … and beyond:

image

Click HERE for more information in German and English.

Monday, October 6, 2014

Prague, December 2014: IEC 61850 Special Training for Protection Engineers

IEC 61850 training courses are under way for some 10 years. The first training course NettedAutomation conducted with 40+ attendees in May 2004 and most other courses focused primarily on the general approach of the “IEC 61850 Framework”. We have trained many groups with general purpose issues like basiccs, history, stacks, applications, and devices. Several training courses were focusing on protection – when NettedAutomation cooperated with protection domain experts.

Today you will find training courses teaching the basics of IEC 61850 all over. The NettedAutomation hands-on training course scheduled for next week (15-17 Oct 2014) in Frankfurt is sold out. We are trying to order a bigger room for more attendees.

BUT: In addition to the general training, there is a need for comprehensive special education for power system PROTECTION !! All major vendors of protection relays offer IEC 61850 connectivity for protection and control. There are many groups of protection engineers that have to be more serious about the use of IEC 61850 devices for protection in a multi-vendor environment.

That is why FMTP and NettedAutomation are offering a 3-days training especially for PROTECTION engineers – conducted by a very experienced senior protection engineer (Andrea Bonetti – who worked for ABB, Megger, STRI).

The first public IEC 61850 protection training conducted by FMTP and NettedAutomation is scheduled as follows:

Prague, Czech Republic, December 8th – 10th
Seminar at HOLIDAY INN Prague Congress Centre

Click HERE for details and registration information.
Click HERE for video messages on the training and the trainers.

Further public events are planned as follows:

16.-18. Feb. 2015, Brussels, BE
18.-20. May 2015, Berlin, DE
Hong Kong

If you are looking for an in-house training, contact us please.

I look forward to meeting you in Prague.

Just published: NIST Framework and Roadmap for Smart Grid Interoperability Standards, Release 3.0

NIST (US National Institute of Standards and Technology) has published the other day the third version of the NIST Framework:

NIST Framework and Roadmap for Smart Grid
Interoperability Standards
Release 3.0
September 2014

The 240 page document gives a very broad and deep inside view into the current situation with regards to crucial interoperability standards.

The list of standards (series) comprises a total of 72 entries. The following 16 (out of 72) entries refer to IEC 61850 documents:

11 – IEC 61850-1
12 – IEC 61850-2
13 – IEC 61850-3
14 – IEC 61850-4
15 – IEC 61850-5
16 – IEC 61850-6
17 – IEC 61850-7-1
18 – IEC 61850-7-2
19 – IEC 61850-7-3
20 – IEC 61850-7-4
21 – IEC 61850-7-410
22 – IEC 61850-7-420
23 – IEC 61850-8-1
24 – IEC 61850-9-2
25 – IEC 61850-10
26 – IEC 61850-90-5

The term “IEC 61850” is used some 90 times. That means: IEC 61850 is a crucial standard in North America. Other IEC standards like IEC 61968/70 (CIM) and IEC 60870-6-TASE.2 (ICCP) or IEEE standards like DNP.3 are as well included in the list.

Click HERE to download the Release 3.0 [pdf, 12.7 MB]

Further standards like IEC 61400-25 will be included soon. There are still PAPs working on some issues, e.g., PAP 16 for Wind Power.

There seems to be no serious discussion anymore if IEC 61850 and related standards are accepted – the main question is: When and How to use the “IEC 61850 Framework”.

Tuesday, September 30, 2014

TÜV SÜD offers tests for IEC 61850 Client, Server, publisher, and subscriber

TÜV SÜD (Munich, Germany) offers a wide range of testing services covering all crucial aspects to help you reaching a high level of interoperability of your device with other devices.

Their services could reduce the risk of non-interoperation on site dramatically! They have experience with edition 1 and edition 2 of the IEC 61850 core parts as well with IEC 61400-25.

Click HERE for a brochure that describes what they offer.

Note that they cover much more than just certification conformance tests. They offer a comprehensive range of support.

Thursday, September 25, 2014

IEC 61400-25 Part 2 and Part 3 CDV approved

The following two documents (CDV – Committee Drafts for Vote) have been accepted by 100 per cent of the Members of IEC TC 88 (in August resp. in September 2014):

Wind turbines – Part 25-2 (Edition 2): Communications for monitoring and control of wind power plants – Information models

Wind turbines - Part 25-3 (Edition 2): Communications for monitoring and control of wind power plants -Information exchange models

Both parts will be published as FDIS soon.

The Information Models are revised to make them consistent with the many other models defined in IEC 61850-7-x. For example in LN WTUR several names of DataObjects change:

SptDmdW to DmdWSpt
SptDmdVAr to DmdVArSpt
SptDmdPF to DmdPFSpt

The Edition 2 of the models is a major step towards harmonization of the information models. The wind power plant objects are now very stable – they are also incorporated into the UML master maintained by IEC TC 57 WG10, WG 17, WG 18, and JWG25 (TC57/TC88):

image

The changes proposed in conjunction of the CDV comments on part 25-2 have already been used for the UML model. Now we have a very stable and harmonized set of information models that can be used for the whole power delivery system – all over.

Additional models are under way, e.g., for condition monitoring (90-3).

Thanks to the UML team!

Wednesday, September 24, 2014

IEC 61850: Is Interchangeability possible?

Yes – If you are seriously requiring it, it is likely that you will get it. Sure: You have to pay for it. You may need to spend some time to find the right vendor … system integrator, consultant to help you getting there. The key issue is education and training.

A very interesting question is currently discussed at LinkedIn:

“Dear all, How far are we from living the of plug & play age of SAS devices (real and full interoperability under IEC 61850 platform)?”

Click HERE for the complete (public) discussion.

One of my contributions is this:

“I guess it would be so easy to reach the goal of "exchangeability": IF (only IF !!) substation owners would specify which parts of their future SAS SHALL BE based on the standard and specify the SCD in sufficient details, in order to simplify, e.g., adding a new Bay Controller coming from a thirty part IED vendor.
That may work fine within one owner (utility) - but not between different owners.
I have seen such an SCD document (6+ MB) ... written by a big TSO ...
I am quite sure that this TSO will reach that goal in the near future - I am not sure if all vendors will like the approach.”

You could easily contribute to the discussion on LinkedIn … or comment on this blog post directly.

Sunday, September 21, 2014

Another Infrastructure: Are Traffic Lights Secure?

Several experts from the University of Michigan have analyzed the safety critical nature of traffic infrastructures. Their findings are summarized in a paper presented in August 2014:

“Green Lights Forever: Analyzing the Security of Traffic Infrastructure”

Abstract: “The safety critical nature of traffic infrastructure requires that it be secure against computer-based attacks, but this is not always the case. We investigate a networked traffic signal system currently deployed in the United States
and discover a number of security flaws that exist due to systemic failures by the designers. We leverage these flaws to create attacks which gain control of the system, and we successfully demonstrate them on the deployment in coordination with authorities. Our attacks show that an adversary can control traffic infrastructure to cause disruption, degrade safety, or gain an unfair advantage.
We make recommendations on how to improve existing systems and discuss the lessons learned for embedded systems security in general.”

It would be nice to read one day down the street:

“Power Flows Forever” ;-)

Click HERE for the paper.

These findings are to some extend applicable to any application domain with similar topologies. The lessons learned could be applied for power delivery infrastructures, too! Or?

Next time you experience a long waiting queue at an intersection or a power black out: It may have been caused by a security flaw.

Note also: No Power no traffic lights!

ENTSO-E: IEC 61850 in Transport Systems for Electric Power is making good progress

The original scope of IEC 61850 in the late 90’s of the last century was “high voltage substations”. Utilities in the domain HV systems did participate in the beginning of the standardization and later-on showed-up seldom – untile recently. After realizing crucial issues in the inter-operation of devices and tools the ENTSO-E started to support the idea of IEC 61850 interoperability in HV substations.

The latest update on these efforts are documented on the ENTSO-E Website.

Click HERE to follow the update.

You will find many interesting topics discussed and useful links to other activities and opportunities to learn more about the success of IEC 61850. There are links to the special event during the IEC 61850 Europe Conference 2014 in Prague; and a link to the event: http://www.iec61850-europe.com/

The last slide presented at the ENTSO-E AhG IEC 61850 @ UCA Booth, Cigré 2014 is remarkable. It shows somebody who seems to have severe headaches:

image

Is this You!? I have seen many people that throw up their hands in despair.

You are not alone! We are here to help you: Training for all experts involved in high voltage substations by really experienced protection and communication experts:

FMTP and NettedAutomation offer special IEC 61850 training for PROTECTION and SCADA applications.

Wednesday, September 17, 2014

IEC 61850-7-410 A1 Ed.2 – Amendment for several new models just published

IEC 61850-7-410 A1 Ed.2 (57/1485/CDV): Amendment 1 to IEC 61850-7-410 Ed.2: Communication networks and systems for power utility automation - Part 7-410: Basic communication structure - Hydroelectric power plants - Communication for monitoring and control

has been published for comments and vote by 2014-12-12

The reason for the amendment is that a number of logical nodes, originally intended for hydropower plants, have been found to have wider usage in power system control. To make them more generic, the logical node names are modified and, in some cases, additional data objects are added. A few completely new logical nodes are also added.

Within the scope of WG18, some of the logical nodes have been modified to allow usage in thermal power plants for power evacuation related components such as excitation, synchronization, frequency and active power control as well as electrical protection devices.

Process control for thermal power plants is not included in the scope of this amendment.

Tuesday, September 16, 2014

Extended Training: FMTP and NettedAutomation cooperate on Practical Training for Power System Automation and Protection

FMTP Power AB (Uppsala, Sweden) and NettedAutomation GmbH (Karlsruhe, Germany) have each long-term experience in the application of standards for protection and control as well for communication and SCADA applications. Both companies have agreed to join their long-term experience in training and consultancy for power system automation and protection.

FMTP and NettedAutomation offer the most comprehensive and vendor-independent education and practical training courses – they combine their knowledge and practical experience with substation control and protection (Mr Andrea Bonetti who worked for ABB, Megger, and STRI) and communication technology and SCADA (Mr Karlheinz Schwarz).

Some years ago Mr Bonetti and Mr Schwarz conducted together several training courses and seminars. They discovered the value of their combined knowledge and experience for customers and decided recently to provide common seminars based on their  combined experience of more than 60 years. The combination of basic Theory and extensive Practical Help is what the industry needs – to keep the power flowing.

First training courses by Andrea Bonetti and Karlheinz Schwarz will be conducted in fall 2014; the first events will be in-house training courses.

FMTP and NettedAutomation will also cooperate with local partners in Asia, South America, North America, Middle East, Africa, and Europe.

If your organization is interested to cooperate, please contact us.

Click HERE for the complete press release.

Click HERE for a brochure on the first 3 days training.

Friday, September 12, 2014

Deutsche Verteilnetzstudie veröffentlicht – mit Hinweisen auf IEC 61850

Das Bundesministeriums für Wirtschaft und Energie (BMWi) hat heute (12. September 2014) die Verteilnetzstudie „Moderne Verteilernetze für Deutschland“ der Öffentlichkeit vorgestellt. Die Studie wurde Ende 2012 vom Bundesministerium für Wirtschaft und Energie (BMWi) in Auftrag gegeben.

Im Koalitionsvertrag der 18. Legislaturperiode „Deutschlands Zukunft gestalten“ wird die vorliegende Studie als Datenbasis für Entscheidungen zu notwendigen Weiterentwicklungen der Anreizregulierung bezeichnet.

Hier klicken, um zur Downloadseite zu gelangen.

“Rainer Baake, Staatssekretär im Bundesministerium für Wirtschaft und Energie, hierzu: "Der Umbau unserer Energieversorgung hin zu mehr erneuerbaren Energien erhöht zweifelsfrei den Investitionsbedarf in die Verteilernetze.
Allerdings macht die Studie zugleich deutlich, dass mit den nun gesetzlich verankerten Ausbaukorridoren des EEG 2014 und einem dadurch besser planbaren Erneuerbaren-Ausbau die Kosteneffizienz des Aus- und Umbaus der Verteilernetze erheblich verbessert wird. Es kommt nun darauf an, das enorme Einsparpotenzial, das der Einsatz intelligenter Methoden bei der Netzplanung und intelligenter Technik im Netzbetrieb bietet, zu nutzen. Die Weiterentwicklung des Regulierungsrahmens ist in der 10-Punkte-Energie-Agenda daher bereits angelegt, und das setzen wir jetzt um."

Die Gutachter kommen in der Studie unter anderem zu dem Ergebnis, dass neue innovative Planungsgrundsätze und neue Technologien, wie beispielsweise regelbare Ortstransformatoren, zentrale Elemente für eine effiziente Integration der erneuerbaren Energien bilden und die Kosteneffizienz des Aus- und Umbaus der Verteilernetze erhöhen.

Die Studie wurde erstellt von einem Gutachterkonsortium bestehend aus dem Institut und Lehrstuhl für Elektrische Anlagen und Energiewirtschaft (IAEW) der RWTH Aachen, dem Oldenburger Institut für Informatik (OFFIS) sowie dem Beratungsunternehmen E-Bridge Consulting GmbH.”

Das wesentliche Ergebnis ist die Forderung, bis zu etwa 40.000 regelbare Ortsnetztransformatoren zu installieren und für weitgehend alle Einspeisungen aus Erneuerbaren Energien-Anlagen für wenige Stunden des Jahres gezielt Abregelungen zuzulassen.

Natürlich gehen fast alle Maßnahmen mit einer deutlichen Zunahme an intelligenten Steuerungen und Kommunikationslösungen einher. Als wesentliche Kommunikationslösungen werden solche empfohlen, die auf IEC 61850-7-420, IEC 60870-5 und IEC 61969 (CIM) basieren. VHPready (als ein Anwender der IEC 61850-7-420) wird lobend erwähnt:

“Die bisherigen Lösungen für das Erzeugungsmanagement sind seit 2006 in Form der Normung der IEC 61850-7-420 zur Kommunikation mit dezentralen Erzeugern in Demoprojekten und verschiedenen Projekten und Initiativen wie VHPready vorangetrieben worden. Produkte von namhaften Herstellern sind bereits im Einsatz.”

Ein interessanter Aspekt ist die Interpretation des Berichts durch den VKU (Verband kommunaler Unternehmen): “… Hingegen kann durch die Steuerung der Verbraucherlast der durch den EE‐Zubau verursachte Netzausbau nicht nennenswert reduziert werden. Der VKU wertet dies als eine klare Absage an den Rollout von Smart Metern in Haushalten.”

Thursday, September 11, 2014

Problem with Wireshark and MMS in the latest versions

You may run into the situation with one of the latest versions of Wireshark, that you cannot display the MMS messages. You may see these frames:

image

What is that? T.125?

If you see this, you have to remove the T.125 Protocol under Analyze:

image

Depending on the version of Wireshark you have, there may be also a need to configure MMS under Edit->Preference->Protocols->PRES:

image

Now you should see MMS again:

image

I am using Wireshark Version 1.12.0

The bug is reported under:
http://comments.gmane.org/gmane.network.wireshark.bugs/62519

Good luck!

IEC 61850 Lab opened by POWER Engineers in Idaho (USA)

Technical support for IEC 61850 based systems, tools and devices is very crucial for the acceptance of the standard. Education and testing are needed all over.

A new competence center for IEC 61850 has opened its doors by POWER Engineers for the North American market. It is no surprise that this kind of services are offered in the USA.

Click HERE for more information.

“We think that IEC 61850 will become much more prevalent in the U.S. market in the near term,” said Scott Olson P.E., senior project manager for smart grid projects at POWER.

Ok, yes, Scott is absolute right!

More to come.

Wednesday, September 10, 2014

Neuer Webauftritt VHPready

Das Industrieforum VHPready hat seit heute einen neuen Webauftritt mit vielen neuen Informationen:

http://www.vhpready.de/

See you there.