Monday, August 7, 2017

ENTSO-E Just Published a New Update on Activities Related to IEC 61850

ENTSO-E is actively supporting the application of IEC 61850.

They believe that "The IEC 61850 Standard for the design of electrical substation automation addresses many crucial aspects of TSO communications, data modeling and engineering in order to reach seamless interoperability of different vendors’ subsystems within the TSO system management architecture."

ENTSO-E published an Update on their activities related to IEC 61850 in July 2017.

ENTSO-E Ad Hoc Group IEC 61850 continued to intensively work on the improvement of the IEC 61850 standard interoperability on two main domains:
  1. At information level (data semantic), the development of the ENTSO-E profile through the Interoperability Specification Tool (ISTool)
  2. At engineering level, by consolidating ENTSO-E requirements that have been formalized into a DC (Document for Comment), approved through the IEC National Committees (NC) voting process, and now encapsulated in the action plan of several task forces of the IEC TC 57 WG10
Click HERE for reading the complete the report.

Comparison of IEC 60870-5-10x, DNP3, and IEC 60870-6-TASE.2 with IEC 61850


In 2008 I published the 3rd version of the document:

Comparison of IEC 60870-5-101/-103/-104, DNP3, and IEC 60870-6-TASE.2 with IEC 61850

This is really the most downloaded document since then - and still in 2017!

Click HERE for getting a copy.

It is interesting that so many people are still interested to see the difference between IEC 61850 and the other IEC TC 57 standard series.

Now, in 2017 we have learned that IEC 61850 goes far beyond the other standard series.

The RTU standards like 104 or DNP3 are still in widespread use. Utilities are expecting that many vendors of RTUs will start to discontinue to supporting these standards.
That is one of many reasons why more utilities are starting to get involved in understanding IEC 61850.

IEC PC 118 Has Published Two CDV Documents Dealing With Smart Grid Communication

IEC PC 118 "SMART GRID USER INTERFACE" has published two new CDV documents available for PUBLIC comments:

Systems interface between customer energy management system and the power management system – Part 10-1: Open Automated Demand Response [118/75/CDV] with 87 pages

Systems interface between customer energy management system and the power management system – Part 10-3: Adapting smart grid user interface to IEC CIM [118/76/CDV] with 27 pages

Both CDV (committee draft for vote) are accessible for PUBLIC comments (http://www.iec.ch/comment).

These documents of IEC PC 118 are likely to have an impact on the work done and under development of IEC TC 57 and IEC TC 65. With your comments a duplication of work may be prevented.

Please use the opportunity to provide your comments through the IEC channel.

IEC 61850-90-9 Models for Electrical Energy Storage Systems

IEC 61850 Part 90-9: Use of IEC 61850 for Electrical Energy Storage Systems is progressing these days. The latest draft describes the basic functions of Electric Energy Storage System (EESS) and the information model of the interface to integrate EESS in intelligent grids and establish the necessary communication with standardised data objects. The next official draft is expected to be published soon.
This draft  is  connected  with  IEC 61850-7-420,  as  well  as  IEC 61850-7-4:2010, explaining how the control system and other functions in a battery based electric energy storage unit utilizes logical nodes and information  exchange services  within the IEC 61850 framework to specify the information exchanged between functions as well as information that individual functions need and generate. The first Edition of IEC 61850-7-420 provides an information model for batteries which was derived from the proposed data objects of part 7-4. Those data objects follow the requirements of batteries that are supposed to be used in substations as an auxiliary power system and as backup power supplies. For this purpose it was sufficient to only model the discharge function. Therefore it is necessary to prepare new logical nodes to be applicable for grid connected electrical energy storage systems.
This draft provides necessary information within 61850 based object model in order to model functions of a battery based electrical energy storage system as a DER unit. For intelligently operated and/or automated grids, storing energy for optimising the grid operation is a core function. Therefore shorter periods of storing energy with charging and discharging capability is also an indispensable function. Charging and discharging operations need to be modelled thoroughly and are in the focus of this technical report.

The draft lists several use-cases found in the real world:

UC1 Retrieve current status and capabilities of EESS
UC2 Set charging power to EESS
UC3 Set discharging power to EESS
UC4 Set Operating mode/ schedule  to EESS
UC5 EESS Alarm / Asset Monitoring

UC1 current capability /status information as an example:

1-2-1 EESS Generic Status Reporting
•  ES-DER on or off
•  Storage available or not available
•  Inverter/converter active power output
•  Inverter/converter reactive output
•  Storage remaining capacity (% and/or kW)
•  Storage Free capacity (% and/or kW)

1-2-2 EESS inverter /converter status
•  Current connect mode:  connected or disconnected at its ECP
•  Inverter on, off, and/or in stand-by status: inverter is switched on (operating), off
(not able to operate), or in stand-by
•  mode, e.g. capable of operating but currently not operating
•  DC current level available for operation: there is sufficient current to operate
•  Value of the output power setpoint
•  Value of the output reactive power setpoint
•  Value of the power factor setpoint as angle (optional)
•  Value of the frequency setpoint (optional)

1-2-3 EESS (battery) internal status
 •  Amp-hour capacity rating
•  Nominal voltage of battery
•  Maximum battery discharge current
•  Maximum battery charge voltage
•  High and Low battery voltage alarm level
•  Rate of output battery voltage change
•  Internal battery voltage
•  Internal battery current
•  State of charge (energy % of maximum charge level)
•  Reserve (Minimum energy charge level allowed, % of maximum charge level)
•  Available Energy (State of charge – Reserve)
•  Type of battery

1-2-4 Power measurements
•  Total Active Power (Total P): Value, High and Low Limits
•  Total Reactive Power (Total Q): Value, High and Low Limits
•  Average Power factor (Total PF): Value, High and Low Limits, and averaging time
•  Phase to ground voltages (VL1ER, …): Value, High and Low Limits

More to come ...

Wednesday, July 26, 2017

IEC TC 88 Published Edition 2 Documents for the Series IEC 61400-25


IEC TC 88 has published the edition 2 of the following two parts of the series IEC 61400-25:

IEC 61400-25-4: Wind energy generation systems -
Part 25-4: Communications for monitoring and control of wind power plants -
Mapping to communication profile
The mappings specified in this part of IEC 61400-25 comprise:
  •  SOAP-based web services,
  •  OPC/XML-DA,
  •  IEC 61850-8-1 MMS,
  •  IEC 60870-5-104,
  •  DNP3.
Click HERE for the Preview.

IEC 61400-25-6: Wind power generation systems -
Part 25-6: Communications for monitoring and control of wind power plants -
Logical node classes and data classes for condition monitoring

Click HERE for the Preview

Note that the mapping to MMS according to IEC 61850-8-1 is the most used communication protocol for applications in the Wind Power Industry.
The modeling approach and the models are now in general compatible with those defined in IEC 61850-7-x. This is a major step forward.
General gateway solutions for IEC 61850 could be used for wind energy generation systems to bridge from Profibus, ProfiNet, Modbus, CAN bus, ... to IEC 60870-5-104 or IEC 61850-8-1.

Friday, July 21, 2017

Data and Communications Security: IEC TC 57 Just Published IEC 62351-7

IEC TC 57 just published IEC 62351-7:2017:
Power systems management and associated information exchange - Data and communications security - Part 7: Network and System Management (NSM) data object models

IEC 62351-7:2017 defines network and system management (NSM) data object models that are specific to power system operations. These NSM data objects will be used to monitor the health of networks and systems, to detect possible security intrusions, and to manage the performance and reliability of the information infrastructure. The goal is to define a set of abstract objects that will allow the remote monitoring of the health and condition of IEDs (Intelligent Electronic Devices), RTUs (Remote Terminal Units), DERs (Distributed Energy Resources) systems and other systems that are important to power system operations. This new edition constitutes a technical revision and includes the following significant technical changes with respect to IEC TS 62351-7 (2010): NSM object data model reviewed and enriched; UML model adopted for NSM objects description; SNMP protocol MIBs translation included as Code Components.
The Code Components included in this IEC standard are also available as electronic machine readable file.
Click HERE for the Preview.
Click HERE for the Code Components.
The standard series IEC 61850 will also come with Code Components when the various 7-x parts will be published as International Standard. This will ease the development and maintenance of engineering and configuration tools ... tremendously.
Check HERE for Code Components ... coming later in 2017 or 2018 ...

Again Security: How do you Protect your Industrial Control System from Electronic Threats?

Industrial Control System (ICS) need to be protected from Electronic Threats - one of the most crucial challenge yesterday, today, and in the future. Joseph Weiss (PE, CISM - one of the real senior experts in the field) uses the term “electronic threats” rather than cyber security because there are many electronic threats to Industrial Control Systems beyond traditional cyber threats (as he says).

Joe Weiss has written a book with more than 300 pages published in 2010 worth to study (and more important TO IMPLEMENT): "Protecting Industrial Control Systems from Electronic Threats"
List of contents:
  1. Industrial Control System Descriptions
  2. Convergence of Industrial Control Systems and Information Technology
  3. Differences between Industrial Control Systems and Information Technology
  4. Electronic Threats to Industrial Control Systems
  5. Myths
  6. Current Personnel Status and Needs
  7. Information Sharing and Disclosure
  8. Industrial Control System Cyber Risk Assessments
  9. Selected Industry Activities
  10. Industrial Control System Security Trends and Observations
  11. Industrial Control System Cyber Security Demonstrations
  12. Selected Case Histories: Malicious Attacks
  13. Selected Case Histories: Unintentional  Incidents
  14. Industrial Control System Incident Categorization
  15. Recommendations
As long as you can read this blog post you could assume that there is enough power for all computers involved in the chain from the server holding this bog to your computer.
When you will see the following message on your screen: "Sorry, we are out power!" don't worry that much - because the only message you CANNOT SEE ON YOUR SCREEN IS: "SORRY; WE ARE OUT OF POWER. No power no screen display. ;-) 
Click HERE for more details on the book.
I guess Joe would have spent another 100 or so pages to talk about IoT vulnerability if he would have written the book now. 
In a report published the other day by Wired you can read:
"On Tuesday, the internet-of-things-focused security firm Senrio revealed a hackable flaw it's calling "Devil's Ivy" a vulnerability in a piece of code called gSOAP widely used in physical security products, potentially allowing faraway attackers to fully disable or take over thousands of models of internet-connected devices from security cameras to sensors to access-card readers.
Using the internet-scanning tool Shodan, Senrio found 14,700 of XXXX's cameras alone that were vulnerable to their attack-at least, before XXXX patched it. And given that's one of the dozens of ONVIF companies alone that use the gSOAP code, Senrio's researchers estimate the total number of affected devices in the millions."
Unbelievable!!
Click HERE for the full Wired report.
How long will you wait to implement more measures to protect your industrial control system?
Start now - latest next Monday.

Tuesday, July 18, 2017

IXXAT (HMS) Offers New POWERFUL Smart Grid Gateways for IEC 61850, IEC 60870-5, Profibus and more

Under the IXXAT brand, HMS delivers connectivity solutions for embedded control, energy, safety and automotive testing.
The new and very powerful IIoT gateways from HMS allow industrial equipment to communicate with power grids based on IEC 60870-5-104 and IEC 61850. In addition they also include Modbus TCP Client/Server and Modbus RTU Master/Slave


IXXAT SG-gateways...
  • enable easy remote control and management of electrical systems
  • allow to log and display application data and energy consumption
  • provide IEC 61850 client/server and IEC 60870-5-104 server support
  • have in-built Modbus TCP Client/Server and Modbus RTU Master/Slave interfaces
  • provide connectivity for CAN Bus, I/O, M-Bus, PROFIBUS, PROFINET and EtherNet/IP based devices
Click HERE for more details in English
Hier klicken für Details in Deutsch

Friday, July 14, 2017

How Much Will The Implementation Of Security Measures Cost?

Almost everybody is talking about security measures in the context of automation and communication systems in factories, power plants, substations, hospitals, ... Talking about the topic is one thing - what's about implementing and sustainable use of secure systems? Hm, a good question.
A news report published on June 13, 2017, under the title
"The “Internet of Things” is way more vulnerable
than you think—and not just to hackers

points out that many - maybe most - devices that communicate using internet technologies are not capable to carry the load needed for reasonable security measures. One paragraph referring to Joe Weiss (a well known expert) is eye-catching:
"Weiss believes that the first step in securing the IoT is to build entirely new devices with faster processors and more memory. In essence, hundreds of billions of dollars’ worth of machines need to be replaced or upgraded significantly."

Click HERE to read the complete report.

I would like to see - at least - more powerful platforms when it comes to new installations. Be aware that the cost of a new platform with implemented state-of-the-art security measures is one thing. Another thing is to implement a more centralized security infrastructures to manage the security.
IEC 62351-9 specifies cryptographic key management, namely how to generate, distribute, revoke, and handle X.509 digital certificates and cryptographic keys to protect digital data and its communication.
Primary goals of the series IEC 62351 are considered for the use of cryptography:
  • Verifying the claimed identity of a message sender (authentication);
  • Verifying that the sender has the right to access the requested data (authorization);
  • Ensuring no one has tampered with a message during transit (integrity);
  • Obscuring the contents of a message from unintended recipients (confidentiality);
  • Associating specific actions with the entity that performed them (non-repudiation).
It is recommended for vendors and users to pay more attention to IEC 62351 (and other standards) and to listen carefully to the experts involved in protecting our infrastructures.
A reasonable white paper on the matter has been published by the BDEW (Germany): "Requirements for Secure Control and Telecommunication Systems".
Click HERE to access the BDEW white paper.
Click HERE for further information (some documents are in English).
Click HERE for a paper discussing the BDEW white paper.

Tuesday, July 11, 2017

Interactive Information about German Power Generation, Load and Export/Import

The German regulator of the electric power network has just opened a new website which gives you a deep inside view in power generation, load and export/import.



Graph from the new website.
Click HERE to access the new website.
Enjoy.
This is a very interesting service ... to see what's going on.

When will Hackers Take Control Over Substations?

I guess most people belief that our power delivery infrastructure is very secure - yes, I agree that this is (still) the case. What's next? There are some publicly visible efforts to change this - obviously.
One of the attempts to approach the power delivery control systems has been made public the other day with the headline:
Attack on Critical Infrastructure Leverages Template Injection
"Attackers are continually trying to find new ways to target users with malware sent via email. Talos has identified an email-based attack targeting the energy sector, including nuclear power, that puts a new spin on the classic word document attachment phish. Typically, malicious Word documents that are sent as attachments to phishing emails will themselves contain a script or macro that executes malicious code. In this case, there is no malicious code in the attachment itself. The attachment instead tries to download a template file over an SMB connection so that the user's credentials can be silently harvested. In addition, this template file could also potentially be used to download other malicious payloads to the victim's computer."
Click HERE to read the full report.
Click HERE for NYTimes report.

Saturday, July 8, 2017

IEC-61850-Hands-On-Training in Deutsch in Karlsruhe (Dezember 2017 und Mai 2018)

NettedAutomation GmbH bietet zwei IEC-61850 Hands-On-Trainingskurse zu unschlagbar günstigen Preisen in Deutsch in Karlsruhe an:

05.-08. Dezember 2017 
14.-17. Mai 2018
04.-07. Dezember 2018


NEU: Zusätzlicher Schwerpunkt wird das Thema "Sicherheitsanforderungen" (BDEW White Paper, ...) für die Energieversorgung sein.
Die drei (3) Blöcke (1 Tag + 2 Tage + 1 Tag) können einzeln oder in Kombination gebucht werden. Sie entscheiden selbst, ob Sie nur einen Tag von Ihrem Arbeitsplatz fern bleiben möchten oder zwei, drei oder vier. Je nachdem, wieviel Zeit Sie investieren wollen oder können und welchen Bedarf Sie haben.


Lernen Sie, wie über 4.300 Teilnehmer vor Ihnen, was IEC 61850 und andere Normen wie IEC 60870-5-10x oder IEC 62351 (Security) bedeuten. Gewinnen Sie einen Einblick in relevante Realisierungen wie die FNN-Steuerbox oder VHPready, die auf IEC 61850 aufbauen. Verstehen Sie, wie Feldbusse (Profibus, Profinet, Modbus, ...) über lostengünstige Gateways in die Anlagen eingebunden werden können.

Im Hands-On-Training lernen Sie die wesentlichen Konzepte der Normenreihe praktisch kennen. Die umfangreiche Trainings-Software dürfen Sie behalten und weiterhin nutzen!


Copyright, 2017-07, Michael Hüter

Der Kurs ist für alle geeignet, die mehr über IEC 61850 erfahren wollen.

HIER klicken, um zur Beschreibung und den Anmeldeunterlagen zu gelangen [pdf, 430 KB].

Beachten Sie auch, dass die meisten Seminare als Inhouse-Kurse stattfinden! Falls Sie Interesse an einem Inhouse-Kurs (in deutsch, englisch, italienisch oder schwedisch) haben sollten kontaktieren Sie uns bitte!

Monday, July 3, 2017

An All NEW Evaluation, Demo, Hands-On Package for IEC 61850 and IEC 61400-25

NettedAutomation GmbH (Karlsruhe, Germany) has released an All NEW Evaluation, Demo, Hands-On Package for IEC 61850 and IEC 61400-25 (EvaDeHon) for immediate download and use!
The new EvaDeHon Package comprises the roles Client, Server, Publisher, and Subscriber running on a PC, HMS (IXXAT, Beck IPC) Gateways, SystemCorp IEDs, ...
The new solutions allow to run multiple IED models (all roles) in parallel on one PC (simulating IEDs of a complete system!) ... and more. The roles and applications are configured directly by SCL files (.cid). You can build your own models and run them with all roles ... if configured.
This Package is based on our 30+ years of experience. We are really proud of offering these tools to the industry today! Sit down, enjoy and relax ...


Copyright, 2017, Michael Hüter

Click HERE to download the documentation only [pdf, 3.2 MB]
Click HERE for downloading the demo package including the documentation and license conditions.

Example: Server and Client on two PCs:


Many topologies on PCs:


... and topologies with gateways:


Click HERE to download the documentation only [pdf, 3.2 MB]
Click HERE for downloading the demo package including the documentation and license conditions.


Monday, June 26, 2017

Update on OPC UA IEC 61850 Companion Specification

The OPC UA IEC 61850 Companion Specification of the OPC Foundation is focusing on gateways that are intended to be used to transfer information fully and accurately through gateways between devices that implement IEC 61850 or OPC UA respectively.
While IEC 61850 is focusing on electricity generation, transmission, distribution, distributed energy resources (DER), and consumption, OPC UA is dealing with non-electrical industrial process activities. It is clear that users require integration of the electrical aspects of a plant with non-electrical aspects.
The information models defined in IEC 61850 were focused during the late 90s on protection and automation of electric power systems. In the meantime the models provide a huge number logical nodes (e.g., STMP = Supervision of temperature with measurement, alarms and trips, or FPID = PID loop control) applicable in most non-electrical applications domains. The communication services (Reporting, Logging, GOOSE, Control, Setting Group Control, ...) are generic for any application domain.
OPC UA’s modelling capabilities is understood to make it possible to transfer data between different systems without losing the semantics of data. Thus the drafted companion specification document describes how IEC 61850 data can exchanged using OPC UA data modelling and services.
Click HERE for more information.
IEC TC 88 PT 25 is currently working on a technical specification: 
Wind turbines - IEC 61400-25-41: Communications for monitoring and control of wind power plants - Mapping to communication profile based on IEC 62541 (OPC UA)
Microsoft has provided an Open-Source OPC UA stack to OPC Foundation! 
The new OPC Foundation .NET reference stack, based on the new .NET Standard Library technology, was developed and optimized by Microsoft to serve as the complete platform-independent infrastructure, from the embedded world to the cloud. This new version is enabled on the following supported platforms: Various Linux distributions, iOS, Android, Windows 7, Windows 8, Windows 8.1, Windows 10, Windows Phone, HoloLens and the Azure cloud.
Click HERE for the press news from the OPC Foundation.
Click HERE for accessing the open source reference stack at Gidhub.
Brief comparison of IEC 61850 and OPC UA:
Standard? Yes for both in IEC.
Available since? IEC 61850 for some 15 years; OPC UA for a few years.
SCADA support? Yes for both.
Real-time support? Yes in IEC 61850; OPC UA is intended to run on TSN (IEEE 802).
Security? Yes for both (IEC 61850 refers to IEC 62351).
Semantic? IEC 61850 has huge, still growing list of models; OPC UA has not yet semantics.
Configuration Language? IEC 61850 has SCL (System Configuration Language); OPC UA has no.
Conformance testing? Yes for both.
Support: By many big and small companies.
Open Source Stack? Yes for IEC 61850 (http://libiec61850.com); yes for OPC UA (from Microsoft, see above).


Wednesday, June 14, 2017

How to Model Thousands of Measurement Signals?

The standard series IEC 61850 was originally developed for high voltage substation automation and protection ... with well defined logical nodes and data objects representing the most crucial signals like status (CSWI.stVal), 3-phase electrical measurements (MMXU.V.phsA ...), temperature supervision (STMP.Tmp, STMP.Alm, ...) and many other signals.
Several applications require huge number of values, e.g.,
  1. Logs (hundreds of status changes over a long period)
  2. Power Quality measurements (hundreds of values of min, max, ...)
  3. Temperature (hundreds or thousands of raw measured or processed values)
The corresponding logical nodes and communication service models would end-up in a lot of overhead in the modelling or in the communication.
I have discussed the first two bullets already inside the standardization groups ... more details may be discussed in a future blog post.
Today, I will discuss the third issue: huge amount of temperature values.
First of all, there are two models for temperature: TTMP (Transducer for a single sensor value) and STMP (Supervision of a single temperature value) with the following excerpt of details:

TTMP.TmpSv.instMag and TTMP.TmpSv.q are the two mandatory data attributes.

STMP.Tmp.mag.f, STMP.Tmp.mag.q, STMP.Tmp.mag.t (Tmp is optional)
STMP.Alm.stVal, STMP.Alm.q, STMP.Alm.t (Alm is optional)
STMP.Trip.stVal, STMP.Trip.q, STMP.Trip.t (Trip is optional)
Second, If you want to communicate just hundreds of temperature values, I would model this application as follows (SIUnits and sample rate ... may be modeled as well):
[Sure, I am aware that multiple instances of TmpSv are not yet standardized ... I would not care a lot at the moment ... it will come anyway. If not, define an extended Data Object TmpSamp with multiplicity 0..*]
TTMP1.
TmpSv1.instMag and TmpSv1.q
TmpSv2.instMag and TmpSv2.q
TmpSv3.instMag and TmpSv3.q
...
TmpSv100.instMag and TmpSv100.q
DataSet="DsTTMP1"
FCDA=TmpSv1.instMag
FCDA=TmpSv2.instMag
FCDA=TmpSv3.instMag
...
FCDA=TmpSv100.instMag
Unbuffered Report CB="UnbTTMP1
Data Set="DsTTMP1" 
trigger option: integrity period 
period: 1 h or ...
----------------------------------------------
TTMP2.
TmpSv1.instMag and TmpSv1.q
TmpSv2.instMag and TmpSv2.q
TmpSv3.instMag and TmpSv3.q
...
TmpSv100.instMag and TmpSv100.q
DataSet="DsTTMP2"
FCDA=TmpSv1.instMag
FCDA=TmpSv2.instMag
FCDA=TmpSv3.instMag
...
FCDA=TmpSv100.instMag
Unbuffered Report CB="UnbTTMP2
Data Set="DsTTMP2" 
trigger option: integrity period 
period: 1 h or ...
---------------------------------------------
TTMP3.
TmpSv1.instMag and TmpSv1.q
TmpSv2.instMag and TmpSv2.q
TmpSv3.instMag and TmpSv3.q
...
TmpSv100.instMag and TmpSv100.q
DataSet="DsTTMP3"
FCDA=TmpSv1.instMag
FCDA=TmpSv2.instMag
FCDA=TmpSv3.instMag
...
FCDA=TmpSv100.instMag
Unbuffered Report CB="UnbTTMP3
Data Set="DsTTMP3" 
trigger option: integrity period 
period: 1 h or ...
---------------------------------------------
Third, If you want to use hundreds of temperature values AND alarms AND trips etc. then STMP would be the right choice. The above modeling approach would be the same.
In addition to the data sets for the measured values, you may also configure data sets for the quality "q", and configure report control blocks with trigger option "data change". You may also add the quality into the other FCDAs ... depending on how crucial the quality is for the client application.

Tuesday, June 13, 2017

Are Blackouts Knocking at the Doors of Substations?

Dear experts interested in secure power delivery systems,
You may have been informed yesterday about one of the latest developments in destroying the power delivery infrastructure: Industroyer.
What is Industroyer? It is "A new threat for industrial control systems" according to Anton Cherepanov (ESET):
"Win32/Industroyer is a sophisticated piece of malware designed to disrupt
the working processes of industrial control systems (ICS), specifically
industrial control systems used in electrical substations.
Those behind the Win32/Industroyer malware have a deep knowledge
and understanding of industrial control systems and, specifically, the
industrial protocols used in electric power systems. Moreover, it seems very
unlikely anyone could write and test such malware without access to the
specialized equipment used in the specific, targeted industrial environment.
Support for four different industrial control protocols, specified in the
standards listed below, has been implemented by the malware authors:
• IEC 60870-5-101 (aka IEC 101)
• IEC 60870-5-104 (aka IEC 104)
• IEC 61850
• OLE for Process Control Data Access (OPC DA)
In addition to all that, the malware authors also wrote a tool that
implements a denial-of-service (DoS) attack against a particular family of
protection relays, ..."

Click HERE for a comprehensive report [pdf].

The Conclusion of the report closes with this statement:

"The commonly-used industrial control protocols used in this malware
were designed decades ago without taking security into consideration.
Therefore, any intrusion into an industrial network with systems using
these protocols should be considered as “game over”."

The protocols used are not the crucial issue! The protocols like IEC 61850 could be protected by the accompanying standard series IEC 62351 (Power systems management and associated information exchange - Data and communications security).
One crucial show stopper is: "Stingy is cool" mentality!!
Securing the systems could be implemented - with far higher costs during development, engineering, configuration, OPERATION, and maintenance.
As long as we all do not accept that the electric power (and other) infrastructures will require a lot more resources to keep the level of today's availability, quality, and security, we will experience more disrupted infrastructures.
Building an infrastructure, operating, and maintaining it are different aspects. The maintenance of our infrastructures will consume definitely more resources than we believe today.
I was shocked to read, that some "friends" believe that the reports about the "Industroyer" are just fake news.
Whatever you believe, one thing is really true: Many systems and devices in the automation domain (substations, ...) are not protected! Believe me!

Saturday, June 10, 2017

CIM-Workshop am 19. Oktober 2017 in Frankfurt

Die DKE lädt zum CIM (Common Information Model)-Workshop 2017 ein!

Ort: Frankfurt/Main
Datum: 19. Oktober 2017

Mit vielen spannenden Themen, u.a.
  • Eine Kurzeinführung in CIM 
  • Viele Anwendungsbeispiele 
  • Vorstellung des Themas CIM in Verteilnetze, Niederspannung 
  • „Life Hack“ – Wir bauen einen Kundenanschluss… 
  • Rolle von CIM in verschiedenen Projekten 
  • Referenzmodelle und CIM 
  • Podiumsdiskussion mit den Themen CIM Blick in die Zukunft, Blockchain, … 
Hier für weitere Informationen klicken.
Introduction to CIM

Thursday, June 8, 2017

What is your Annual Cybersecurity Incident Bill?

"Although the majority of industrial organizations believe they are well-prepared for cybersecurity incidents, this confidence may be not well-founded: every second ICS company experienced between one and five incidents last year, according to a survey conducted by Kaspersky Lab. On average, ineffective cybersecurity costs industrial organizations up to $497K per year."

Click HERE to read more details.

Many ICS (Industrial Control Systems) are also used in power system applications. So, what is the situation there? Likely similar to the industrial domain.