Friday, September 10, 2010

ABB's Entry Points for IEC 61850 related Information

ABB has posted a huge source of information about IEC 61850 and applications in Substations all over. It's a nice starting point to see what they are doing with regard to IEC 61850.

Click HERE or HERE for two ABB web pages with many good explanations and links to useful papers and other documents.

GOOSER - Prüfungen von Anlagen mit GOOSE-Nachrichten

Ein echtes universelles IEC 61850-Prüf-Interface ist verfügbar. Der Gooser von Megger verbindet konventionelle Relais-Prüfgeräte mit IEC 61850 basierten Systemen. Der "Gooser" wird also eine echte Alternative zu aufwendigen, neuen Schutz-Prüfsysteme mit integrierter IEC-61850-Schnittstelle gesehen.

Click HIER zum Download einer aktuellen Veröffentlichung über den GOOSER in der np.

FREE IEC 61850/61400-25 DLL - One Download per Hour

The FREE IEC 61850/61400-25 Evaluation/Starter Kit is now available for download since August 31, 2010. The kit provides a DLL for simple IEC 61850 Client, Server, Publisher, and Subscriber Applications running on a PC under Windows.

In average one kit has been downloaded per hour since then! This DLL and its API seems to be one of the crucial Highlights of Standardized Information Models, Information Exchange Methods, and Configuration Language! It brings you the Best after the holiday season (in many countries in the northern hemisphere - or before in the southern).

You simply can't get it for less - Its's FREE.

DO NOT Click HERE if you want to keep going with your legacy solution.

Phoenix Contact is Hiring a Software Developer with IEC 61850 Experience

Phoenix Contact is hiring a Software Developer for Embedded Systems with IEC 61850 experience!
Good Luck!

Click HERE for the job offering [German].

Automation goes Power: Phoenix Contact starts Road Show "Energy Management"

Electric Power systems are on the radar screen of companies that - traditionally - did their business in the factories. One of the well known German companies is Phoenix Contact. What are these companies looking for? More revenue? Very likely.

During the last 20 years there was very little automation in the power industry influenced by factory automation vendors and their solutions. This will change in a fast pace: One of the leading experts (Roland Bent, CEO of Phoenix Contact) stated during the VDI Congress that the market for automation systems in the utility domain (electric power, water, ..., clean and green technologies) will be three times bigger in 2030 than today's factory automation. Wow.

Click HERE for some more details ... what they are looking for ...

Click HERE to read the announcement for an Energy Management Road Show [German].

Thursday, September 9, 2010

Substation Automation Handbook

The electrical Grid is about to be transformed into a Smart(er) Grid. The most crucial aspect is still (and I hope for ever) the electrical system - a system of generators, wires, transformers, switches, etc bound together by some laws. Substations are important elements in the system. For all people that need to understand the challenge of the automation of electrical systems should read the

The Substation Automation Handbook written by Dr. Klaus-Peter Brand, Volker Lohmann, Dr. Wolfgang Wimmer

Cover_cor

This book is a comprehensive description of Substation Automation and the coordination with Network Operation to obtain both performance and cost benefits by enabling enhanced Power System Management ... including the new standard IEC 61850.

Over the past decade the electricity supply industry has been subjected to dramatic changes. World-wide the trend is to restructure vertically integrated utilities catering for generation, transmission and distributions into smaller "unbundled" companies. The new plant owners are pushed to minimize costs through greater utilization of assets. The book helps to understand the needed solutions to get there.

Click HERE to read more about the book and how to order it.

Wednesday, September 8, 2010

IEC61850@CHIP - Forum for API usage open

Beck IPC has opened a Forum for the IEC 61850 Stack API. What to do if the client does not start? What if ...?

Click HERE to proceed to the IEC 61850 Forum at the website of Beck IPC

Special Course on Key Standards for Smart Grids in Dallas (TX): IEC 61850, IEC 61400-25 and DNP3

A two-day special seminar and training on IEC 61850, IEC 61400-25 and DNP3 will be conducted by Karlheinz Schwarz (Editor of IEC 61850, IEC 61400-25, member of NIST PAP16, ...) at:

Remote 2010 Conference & Expo
October 19-20, 2010 - Dallas, Texas

In this comprehensive 2-day workshop students learn the fundamental concepts and vision of the NIST Smart Grid activities and of the IEC 61850 standard series. Students compare well known solutions like DNP3 and the new OPC UA with IEC 61850 (IEC 61400-25, Wind Turbines) and discuss the strength each method offers. All the IEC 61850 standards, their extensions, and many application domains are briefly discussed and the class delves into IEC 61850 real-time and client/server solutions. Each student (that brings his own PC) will do some hands-on training with IEC 61850 client/server communication and GOOSE messaging. We are using freely available evaluation software running under Windows. Two PCs could be connected to see messages on the Ethernet wire.

Click HERE for more details and registration information.

Tuesday, September 7, 2010

Redundant Ethernet for Communication in Substation Automation Systems according to IEC 61850

The High-availability Seamless Redundancy protocol (HSR) was designed to meet the highest availability requirements of industrial applications (such as substation automation or motion control) with an Ethernet based communication infrastructure. IEC 61850-90-4 "Network Engineering Guidelines" recommends to use HSR for particular applications.

In the context of the project supported by the Swiss innovation promotion agency CTI, ZHAW is evaluating the feasibility of HSR. Project partners are ABB, Hirschmann, and Siemens. These companies have demonstrated the new solution during the recent Cigré Exhibition in Paris (end of August 2010).

Click HERE for a report in English.
Click HERE for a report in German.

Saturday, September 4, 2010

NIST Smart Grid - Cyber Security Guidelines Released

The three volumes of the "Guidelines for Smart Grid Cyber Security (NISTIR 7628)" have been published by NIST end of August 2010.

The report presents an analytical framework that organizations can use to develop effective cyber security strategies tailored to their particular combinations of Smart Grid-related characteristics, risks, and vulnerabilities. Organizations in the diverse community of Smart Grid stakeholders—from utilities to providers of energy management services to manufacturers of electric vehicles and charging stations—can use the methods and supporting information presented in this report as guidance for assessing risk and identifying and applying appropriate security requirements.

This document is a companion document to the NIST Framework and Roadmap for Smart Grid Interoperability Standards, Release 1.0 (NIST SP 1108), which NIST issued on January 19, 2010.

Click HERE to download Volume 1
Click HERE to download Volume 2
Click HERE to download Volume 3
Click HERE to download the NIST Framework and Roadmap for Smart Grid Interoperability Standards, R1.0

Does IEC 61850 provide Security Measures? - Yes

Friday, September 3, 2010

IEC 61850 Tissue Database for Edition 2

The first four (4) parts of IEC 61850 have been published as Edition 2: Part 6, Part 7-4, Part 7-3, and Part 7-2.

The Tissue Database (technical issues) is now open for posting tissues on these four new parts (Edition 2):

www.tissue.iec61850.com

The first tissues have already been posted for Edition 2 documents. If you have any tissue to be reported to the editors of the standards please check with the tissue database - maybe your issue has already been posted.

The Tissue Database for IEC 61400-25 is also open:

www.tissue.iec61400-25.com

Click HERE for some general remarks on Edition 1 and Edition 2.

Update: NIST SGIP - Special Cross-PAP Session on Information Models for Generators and Storage

Please find the agenda for the upcoming meeting of the special group in St. Louis (MS):

Special Cross-PAP Session:
Coordinated Object Modeling for Generators and Storage
SGIP Fall Meeting
September 15, 2010, St. Louis, Missouri
12:30 to 3:00 PM

This Cross-PAP issues session is your chance to participate in discussions on coordinating consistent object models and information exchange requirements for different generator types (e.g., wind turbines, hydro power plants, PV systems, and storage) across multiple domains (consumer, distribution, and transmission). This session is expected to aid in producing consistent object model requirements (where possible) being developed for example by PAPs 7 and 16 for IEC 61850-7-420 (DER), IEC 61850-7-410 (hydro) and IEC 61400-25 (wind). The consistent generator control, monitoring and protection requirements are to be coordinated and combined with requirements of other PAPs including 3, 4, 9, and 10. There are several areas in which the various application domains highly benefit from consistent information models, consistent information exchange and security steps. The interface between power generation and the control center and between aggregators and distributed generators are obvious examples. This session is intended to provide overviews of and to initiate coordination of activities required to develop consistent object models for different generator/storage types across different Smart Grid domains.

Topics presented and discussed include:

  • Status of object models for wind turbines, hydro power plants, PV systems, other distributed energy resources – (Karlheinz Schwarz, editor of IEC 61850 and IEC 61400-25) – 30 minutes
  • IEC 61400-25-2 transmission level wind generator standard with first two logical nodes that define active power control and reactive power control (Bill Moncrief) – 20 minutes
  • Key ES-DER Use Cases - The necessity of establishing a set of core functions as a foundation for standard protocols and device interoperability. Results from a collaborative industry activity. (Brian Seal) – 20 minutes
  • IEC 61850-7-420 for ES-DER functions, focusing on pricing signals, volt/var schedules, direct control, and broadcast control, as well as cyber security (Frances Cleveland, editor of IEC 61850-7-420 and IEC 62351) – 20 minutes
  • Common modeling concepts, key services like "report-by-exception" and configuration language – Mapping of 61850 to Webservices (IEC 61400-25-4), to DNP3 and to SEP 2.0 (Frances) – 30 min
  • IEC 61850-on-a-chip (Karlheinz Schwarz) – 15 minutes

Related standards and PAPs:

  • IEC 61850-7-420, IEC 61400-25, IEC 62351
  • IEEE P 1547.8, IEEE P174
  • DNP3, SEP 2.0, MultiSpeak, CIM
  • PAPs: Developed by 7 and 16; used by 3, 4, 9, 10, 8 and 14

Tuesday, August 31, 2010

FREE IEC 61850/61400-25 Evaluation/Starter Kit

A FREE IEC 61850/61400-25 Evaluation/Starter Kit is now available for immediate download and use. The wait for a FREE IEC 61850/61400-25 Evaluation/Starter Kit is over - here it is for immediate use.

SystemCorp (Perth, Australia) and NettedAutomation offer an IEC 61850/61400-25 DLL (Dynamic Link Library) and three Application examples using the DLL (PIS10.dll; providing a simple stack API):

  • C Server Application (simple Console) 
  • C Client Application (simple Console) 
  • C#/.Net Client Application (runs under XP, Vista, Windows 7)

The Kit contains executable software and the source code of the C and .Net Applications (projects) as well as "Getting started manuals". The PIS10.dll is based on the IEC 61850 stack developed by SystemCorp. The client and server (publisher/subscriber - GOOSE) run on one machine or on different machines as depicted below:

Getting_Started_DLL_IEC6-cor

You can use these source code of the application examples and modify them according to your needs. The configuration of the Server AND the Client done by ICD files (according to IEC 61850-6, SCL) - no need for self-description; the model is build at start time. This client/Server package is applicable for M2M (machine to machine) communication. The IEDScout could be used as a Browser-Client as well. Modified applications would require a modified ICD file as well. The "ICD Designer" - a tool to design ICD files - will be available within a week or so.

The services supported are: Association, GetDataObjectValues, SetDataObjectValues, Control, Reporting, GOOSE, ...

NettedAutomation GmbH offers a new services for the integration of the PIS10 stack (DLL, ...) into your application:

Support will be provided by our experienced application programmer: Andreas Pfefferle. Andreas is familiar with Substation Automation, RTUs, IEC 60870-5-10x, protocol integration, ... SystemCorp PIS10-Stack API and many other power utility applications.

Click HERE to Download the IEC 61850/61400-25 Evaluation/Starter Kit
(The Kit comprises first a readme.txt file and four (4) zip files - each file can be downloaded individually; You need at least the <<Console-Server-Client_2010-08-31>> to get the server; to run the client with another server you need to change the ICD file accordingly).
IF you have an Account for downloading content from www.nettedautomation.com then you can use your email address and password. If you have forgotten the password, just enter your email address in the field "Email (required)" and click on the button "I agree ... continue" at the end - you will receive your password. Or just enter your email and further information and you will receive a password immediately.

Enjoy.

Monday, August 30, 2010

NIST SGIP - Special Cross-PAP Session on Coordinated Information Modeling for Generators and Storage

The fall face-to-face meeting of the NIST SGIP (Smart Grid Interoperability Panel) will take place in St. Louis (MS) from September 14-16, 2010.

A Special Cross-PAP Session on Coordinated Information Modeling for Generators and Storage is intended to provide overviews of and to initiate coordination of activities required to develop consistent information models for different generator/storage types across different Smart Grid domains. This Cross-PAP issues session is your chance to participate in discussions on coordinating consistent information models and information exchange requirements for different generator types (e.g., wind turbines [IEC 61400-25-2], hydro power plants [IEC 61850-7-410], PV systems, and storage [IEC 61850-7-420], ...) across multiple domains (consumer, distribution, and transmission).
Session is scheduled for Wednesday, Sept. 15th (12:30-15:00)

Click HERE for the full program and other details of the meeting.

Please note that Mr. Karlheinz Schwarz (member of PAP16, editor IEC 61850, IEC 61400-25) will be in St. Louis on Sept. 15 and 16 ... to meet you ...

Friday, August 27, 2010

SystemCorp and NettedAutomation exhibit at DistribuTech 2011

SystemCorp Embedded Technology Pty Ltd (Perth, WA/Australia) and NettedAutomation GmbH (Karlsruhe/Germany) will exhibit the latest developments in lite implementations of IEC 61850 and IEC 61400-25, gateways between IEC 61850/61400-25, DNP3, IEC 60870-5, Modbus, RTUs, Bay controller, PLC programming IEC 61131-3, starter kits, ... training opportunities, training tools at booth 2822 at the DistribuTech 2011 Exhibition in San Diego (CA), 1.-3. February 2010.

Please plan for a meeting the "IEC 61850 Lite" experts.

Click HERE for the floor plan and booth 2822.

Thursday, August 26, 2010

Draft Technical Report - IEC 61850 for Synchrophasor

Draft IEC 61850-90-5 TR Ed. 1 – Use of IEC 61850 to transmit synchrophasor information according to IEEE C37.118 has been published as draft Technical Report (57/1086/DC). Comments by 2010-10-01.

This technical report describes how to use IEC 61850 to transmit synchrophasor information according to IEEE C37.118. Later, once the report is approved and published, results will be integrated as amendments in the relevant parts of the IEC 61850 standard.
This document contains a first draft of that report. As a significant part, it includes new mappings of the IEC 61850 GOOSE and sampled value services that can be used for a wide area communication.

Two new control blocks are defined for IP networks:
• The sending of stream information (e.g. Sampled Values)
• The sending of event driven information (e.g. GOOSE)

Two possibilities are drafted:

The streams for SMV and GOOSE will be transmitted over a transport profile that utilizes IPv4 or IPv6, and TCP as well as UDP.

Once these models are extended in the ACSI (IEC 61850-7-2) they may also be used for Reporting over UDP.

FDIS of IEC 61850-7-3 Edition 2 out for final Ballot

IEC Central Office has published the FDIS of IEC 61850-7-3 Edition 2 (57/1087/FDIS). The ballot closes 2010-10-29.

The second edition comprises 39 Common Data Classes (CDC):

  • defines new common data classes used for new standards defining object models for other domains based on IEC 61850 and for the representation of statistical and historical data,
  • provides clarifications and corrections to the first edition of IEC 61850-7-3.

Common data class specifications for status information

  1. Single point status (SPS)
    Double point status (DPS)
    Integer status (INS)
  2. Enumerated status (ENS) - NEW
  3. Protection activation information (ACT)
  4. Directional protection activation information (ACD)
  5. Security violation counting (SEC)
  6. Binary counter reading (BCR)
  7. Histogram (HST) - NEW
  8. Visible string status (VSS) - NEW

Common data class specifications for measurand information

  1. Measured value (MV)
  2. Complex measured value (CMV)
  3. Sampled value (SAV)
  4. Phase to ground/neutral related measured values of a three-phase system (WYE)
  5. Phase to phase related measured values of a three-phase system (DEL)
  6. Sequence (SEQ)
  7. Harmonic value (HMV)
  8. Harmonic value for WYE (HWYE)
  9. Harmonic value for DEL (HDEL)

Common data class specifications for controls

  1. Controllable single point (SPC)
  2. Controllable double point (DPC)
  3. Controllable integer status (INC)
  4. Controllable enumerated status (ENC) - NEW
  5. Binary controlled step position information (BSC)
  6. Integer controlled step position information (ISC)
  7. Controllable analogue process value (APC)
  8. Binary controlled analog process value (BAC) - NEW

Common data class specifications for status settings

  1. Single point setting (SPG)
  2. Integer status setting (ING)
  3. Enumerated status setting (ENG) - NEW
  4. Object reference setting (ORG) - NEW
  5. Time setting group (TSG) - NEW
  6. Currency setting group (CUG) - NEW
  7. Visible string setting (VSG)- NEW

Common data class specifications for analogue settings

  1. Analogue setting (ASG)
  2. Setting curve (CURVE)
  3. Curve shape setting (CSG) - NEW

Common data class specifications for description information

  1. Device name plate (DPL)
  2. Logical node name plate (LPL)
  3. Curve shape description (CSD)

ICS-CERT Advice on STUXNET Maleware Mitigation

In July, ICS-CERT published an advisory and a series of updates regarding the Stuxnet malware entitled “ICSA-10-201- USB Malware Targeting Siemens Control Software.”
Stuxnet makes use of a previously unpatched Windows vulnerability. Since then, ICS-CERT has continued analysis of the Stuxnet malware in an effort to determine more about its capabilities and intent. As the analysis has progressed, understanding of the malware sophistication has continued to increase.

Click HERE for the complete report [pdf].
Click HERE for details published by Symantec.
Click HERE to visit the website (in German) of GAI NetConsultant (Berlin), a well experienced team of security experts.