IEC TC 57 has published a Draft Technical Report (57/1817/DTR; 84 pages) with guidelines on how to apply IEC 61850 for substation automation:
Communication networks and systems for power utility automation –
Part 7-500: Basic information and communication structure – Use of logical nodes for modeling application functions and related concepts and guidelines for substations
Voting closes 2017-02-17
This is a document that you MUST read when you are involved in substation automation.
This Technical Report of IEC 61850 describes the use of the information model for devices and functions of IEC 61850 in applications in substation automation systems but it may be used as informative input also for the modeling of any other application domain. In particular, it describes the use of compatible logical node names and data objects names for communication between Intelligent Electronic Devices (IED) for use cases. This includes the relationship between Logical Nodes and Data Objects for the given use cases. ...
Part 7-5 describes in examples the use of logical nodes for modeling application functions and related concepts and guidelines in general independently from any application domain respectively valid for all application domains in the electric power system (substation automation, distributed energy resources, hydro power, wind power, etc.). This part 7-500 describes in examples the use of logical nodes for application functions in substation automation including also line protection between substations. It implies also some tutorial material where helpful. But it is recommended to read parts IEC 61850-5 and IEC 61850-7-1 in conjunction with IEC 61850-7-3 and IEC 61850-7-2 first.
Communication networks and systems for power utility automation –
Part 7-500: Basic information and communication structure – Use of logical nodes for modeling application functions and related concepts and guidelines for substations
Voting closes 2017-02-17
This is a document that you MUST read when you are involved in substation automation.
This Technical Report of IEC 61850 describes the use of the information model for devices and functions of IEC 61850 in applications in substation automation systems but it may be used as informative input also for the modeling of any other application domain. In particular, it describes the use of compatible logical node names and data objects names for communication between Intelligent Electronic Devices (IED) for use cases. This includes the relationship between Logical Nodes and Data Objects for the given use cases. ...
Part 7-5 describes in examples the use of logical nodes for modeling application functions and related concepts and guidelines in general independently from any application domain respectively valid for all application domains in the electric power system (substation automation, distributed energy resources, hydro power, wind power, etc.). This part 7-500 describes in examples the use of logical nodes for application functions in substation automation including also line protection between substations. It implies also some tutorial material where helpful. But it is recommended to read parts IEC 61850-5 and IEC 61850-7-1 in conjunction with IEC 61850-7-3 and IEC 61850-7-2 first.
No comments:
Post a Comment