Please find another frequency deviation detected on 2020-11-05
Message time : 05.11.2020 06:01:36 MEZ
Message : UCTE high frequency
Mains frequency : 50,122 Hz
Mains load difference : 1717,4 MW
IEC 61850, IEC 61400-25, IEC 61970 (CIM), IEC 60870-5, DNP3, IEC 62351 (Security), ...
Please find another frequency deviation detected on 2020-11-05
Message time : 05.11.2020 06:01:36 MEZ
Message : UCTE high frequency
Mains frequency : 50,122 Hz
Mains load difference : 1717,4 MW
Please find another frequency deviation detected on 2020-11-02.
Message time : 02.11.2020 21:01:14 MEZ
Message : UCTE low frequency
Mains frequency : 49,896 Hz
Mains load difference : -1441,3 MW
Three Ukrainian power distribution companies sustained a cyberattack in western Ukraine on 23 December 2015. As the forensic information is extensive from a technical point of view, it is an opportunity to put
ISA/IEC 62443-3-3
Industrial communication networks - Network and system security
- Part 3-3: System security requirements and security levels
to the test with a real-life example. Several sources were used for this purpose that, overall, provide unusually detailed information.
Click HERE for the report "Ukrainian Power Grids Cyberattack - A Forensic Analysis Based On ISA/IEC 62443" ... worth to read!
Click HERE for a white paper on the series IEC 62443
Click HERE for a preview of the standard:
In a white paper published by Schneider Electric you can read:
"The IEC 61499 standard sets a foundation for industrial automation application portability that creates wide-ranging benefits, including easy IT/OT system convergence, improved return-on-investment on software applications that can run independent of any hardware platform, and engineering design efficiency that radically speeds up new product time-to-market. ... Plug and Produce Systems: The move to automation systems based on IEC 61499 is more than a simple technology change. It has the potential to fundamentally change the way processes and machines are designed."
Click HERE for a new white paper on IEC 61499 from Schneider Electric.
Click HERE for a list of posts related to IEC 61499 ... and IEC 61850.
Ethernet is well known globally as solution for communication. Ethernet was hated and liked for the last 40 years or so ... there have been alternative solutions developed that were marketed as much easier, faster, deterministic, ... think of Tokenbus (IEEE 804), Profibus, ... and many others.
Now we see a new version: Single Pair Ethernet (SPE). SPE can bring fast Ethernet (up to 1 GBit/s) and power to the field level using just one twisted wire pair ... enabling application of protocols using TCP/IP.
Click HERE for a general description.
Click HERE for a nice presentation by IEEE experts (January 2019)
SPE is a new technology to replace CANbus in automobiles (cars, trucks, busses, ... trains) and fieldbusses. SPE is a layer 1 standard ... so it can be used for Profinet, Ethercat, ... and it could run TCP/IP.
SPE is more intended to replace fieldbus systems ... here my dream of the late 80s becomes true:
Fieldbus Standardization - Another Way to Go
http://blog.nettedautomation.com/2017/05/tsn-fieldbus-standardization-another.html
additional posts related to the topic:
http://blog.nettedautomation.com/search?q=another+way
The use of SPE for connecting sensors to the cloud is to follow a trend ... it may increase the sales of component manufacturers.
When I wrote my Diploma Thesis in 1982 (at Siemens) I was asked to analyze Ethernet ... the idea was cancelled because of the very very expensive MAU ... needed two ... each for 23,000 USD ... total of 46,000 USD ... no way to get approval to spend that amount for a "standard" Diploma Thesis ...
It took some 40 years to get to SPE - likely the real Ethernet ... ;-)
Too late for me ... just retired this year with 67 ...
One crucial challenge is here: HOW to SECURE a huge number of end nodes (sensors, actuators ...) directly connected to the clouds or data lakes? Compare the situation with Smart(er) Grids: In Smart(er) Grids it is intended to connect millions of smart meters to the entities (clouds!?) that use the data for billing and further applications like controlling millions of inverters or power users.
In the German power system there is a requirement to use the so-called Smart Meter Gateway (SMG) to provide highly secure communication channels!
Click HERE to check what has to be implemented ... many published Megabyte pdf documentation of the required specification like: "Protection Profile for the Gateway of a Smart Metering System (Smart-Meter-Gateway PP)" ... by the German BSI.
It took many years before we have seen the first certified Smart Meter Gateway offered at the market. And be aware: The Administration of this infrastructure is very complex and ... far away from cheap and affordable by "everyone".
Many similar huge "security systems" would be required to connect the billions of smart sensors and actuators through Single Pair Ethernet to some centralized entities ...
SPE is nice - BUT to build secure distributed systems it is required to develop also new security solutions that are as simple as Single Pair Ethernet!!
We have to look at the complete SYSTEM COST - not just at the possibilities of a new physical layers ... the SPE increases the problems of implementing secure systems, because it is easier and cheap to build a huge mashed network of millions of end nodes ... that may not perfectly secured!
The frequency of the European Interconnected Electrical Grid (UCTE) is under stress. The frequency should be 50 Hz ... as you know. Click HERE for an UCTE background paper. Click HERE for details and basics of the Nordic Grid.
The network frequency is uniform in a power supply network and, apart from minor deviations from the nominal value, constant over time. The frequency changed today and earlier more than what usually is expected.
Here is some information about todays situation at 11:00 a.m.:
Time : 21.10.2020 11:02:35 MESZ
Message : UCTE low frequency
Mains frequency : 49,886 Hz
Mains load difference : -1594,6 MW
UPDATE 2020-11-03
Message time : 02.11.2020 21:01:14 MEZ
Message : UCTE low frequency
Mains frequency : 49,896 Hz
Mains load difference : -1441,3 MW
www.pc-projekte.de (the content can easily be translated - with Google)
You may register to receive messages like the one above:
https://pc-projekte.lima-city.de/ucte-netzfrequenz-infodienst.html
Note that these messages carry just privately generated information about specific events of the frequency of the ENTSO-E Network in Continental Europe (former UCTE).
The diagram on the left part is derived from:
https://gridradar.net/netzfrequenz.html
Hope you will find this post informative.
The final 245 page committee report (September 2020) on the problems with the Boeing 737 MAX tells stories that we (as engineers) could not believe! Or?
There are are many very crucial details that have been reported. You have to read the report on your own ...
Click HERE for the report.
Here are two excerpts that made me very sad:
"The story of the Boeing 737 MAX was never expected to be associated with catastrophe. It was supposed to be a story of American ingenuity and technological success—a modern, more fuelefficient airplane that had already become the manufacturing giant’s best-selling jet in its storied history prior to the first MAX crash ..." ... Obviously it was too easy to cheat ... in order to make more sales ... to earn more money, to get richer ... to ... what ever.
"... FAA delegated some certification activities to Boeing that it should have retained. In the case of the 737 MAX, in 2013, the FAA originally delegated 28 of 87 tasks to Boeing. However, this number rose to 79 of 91 activities by November 2016, four months prior to final certification of the 737 MAX aircraft."
Be aware that is very common in the industry to allow self-certification ... so, the results may be similar as with the 737 MAX ... non-conformity of a protection relay may lead to severe blackouts and ...
One obvious reason for these behavior of humans these days could be found in
"And for this cause God sendeth them a working of error, that they should believe a lie: that they all might be judged who believed not the truth, but had pleasure in unrighteousness."
Bible 2. Thessalonians 2:11-12
IEC TC 57 has published five additional code components document as listed in the figure:
These documents are very helpful ... they provide the main parts of the corresponding information models.
Click HERE to see the full list of the 18 published code components.
IEC 61850 is one of the most crucial standard series for automation - in power systems and beyond. There are still just a few experts that really understand what it is all about.
If you want to learn a bit more, you may attend the VIRTUAL Conference 26-30 October 2020 ... You don't need to travel ... don't need to stay at a hotel ... stay at home with your family ...
Get a discount by registering before 28 August 2020.
Click HERE for the details.