IXXAT Smart Grid Gateway With NEW Possibilities

IXXAT (HMS) has offered their Smart Grid Gateways for some time. Click HERE for some blog posts that give you a good overview of the possibilities so far (HERE for HMS or HERE for Beck).
The other day IXXAT has published an extended range of possibilities to share information between many different communication solutions in almost ALL automation applications:

SG-gateway IO
SG-gateway M-Bus Master
SG-gateway EtherNet/IP
SG-gateway PROFIBUS
SG-gateway PROFINET

New:

SG-gateway Media Converter
SG-gateway Switch

All types support as well:

Modbus-RTU master/slave via RS232/485
Modbus-TCP master/slave
DHCP server, SNTP, Network trace (pcap), SNMPv2c
OPC-UA server
MQTT
Codesys network variables

Optional:

IEC 60870-5-104 client/server with redundancy (Norwegian User Convention)
IEC 60871-5-101 master/slave
IEC 61850 client/server (both roles and GOOSE pub/sub are supported simultaneous)
IEC 61850 GOOSE publisher/subscriber
Outstation DNP3
Hardware versions with 3G or 4G modem

Click HERE to visit the IXXAT website for an overview (German).
Click HERE to download a new 12 page pdf bochure (German).

Sunday, October 6, 2019

Next week: IXXAT Smart Grid Gateways at IEC 61850 Global 2019 in London, UK

IXXAT (HMS) will be available at the conference to demonstrate you the latest gateway family supporting IEC 61850, IEC 60870-5-104, Profibus, ProfiNet, Ethernet/IP, M-Bus, ...

IEC 61850 Global 2019
London, UK
Oct 14, 2019, 02:00 AM - Oct 19, 2019, 02:00 AM

Drawing together 150+ IEC 61850 specialists and implementation leaders, this end-user-driven programme focuses on achieving multi-vendor, multi-edition interoperability within the substation and across the wider smart grid.

Click HERE for more details on the event.

New IIoT gateways from HMS allow industrial equipment to communicate with smart grids ...

Click HERE for more details to solve smart grid information models and communications.

Note that the gateway will come with MQTT as well ...

Click HERE for the Gateway with MQTT support.

Monday, August 5, 2019

Beck IPC offers MQTT@CHIP in addition to IEC 61850 and other protocols

Beck IPC (Wetzlar, Germany, a subsidary of HMS) is known for their solutions on a single CHIP offering support for IEC 60870-5-104, IEC 61850, Modbus, CANBus, Profibus, Profinet, OPC UA, ... now offers MQTT@CHIP as an additional solution.



The MQTT can be configured on the WEB PLC like it is implemented for other protocols:



In the above example I have mapped a signal from an IEC 61850 Server the signal MMXU1.TotW.instMag.f to a MQTT message. This way you can tag the signal as a JSON Object!!

JSON Objekte:
{ „MMXU01.TotW.instMag.f“:  2325, „MMXU01.Hz.instMag.f“:  49.98 }

Message specification:



This way you can send MQTT messages with values from any other protocol or from the IEC 61850 client or server model. This way you can even map to/from GOOSE messages.

I have used the solution running on the IXXAT Smart Grid Gateway. The WEB PLC version 19.2 is required to run MQTT on the gateway.

Very well done!

Monday, August 21, 2017

New Application Example for EvaDeHon Package

We have posted a new example extending the use of the Evaluation, Demonstration and Hands-On (EvaDeHon) Package.

We will publish from time to time additional models and documentation for interesting applications. The objective is to help you to understand the various topologies and possibilities to use the IEC 61850 technology for the process information exchange.

One focus is on the application of the IXXAT (HMS) Smart Grid Gateways.

The example offers polling and reporting (Server on PC, Client on IXXAT WEB-PLC Gateway). The download contains the client CID for the gateway, the server CID and the JSON file for the PC. The gateway polls every 2 seconds and receives reports every 5 seconds - these intervals can be configured. Additionally it includes some specific documentation.



Click HERE for more information.

Monday, July 3, 2017

An All NEW Evaluation, Demo, Hands-On Package for IEC 61850 and IEC 61400-25

NettedAutomation GmbH (Karlsruhe, Germany) has released an All NEW Evaluation, Demo, Hands-On Package for IEC 61850 and IEC 61400-25 (EvaDeHon) for immediate download and use!
The new EvaDeHon Package comprises the roles Client, Server, Publisher, and Subscriber running on a PC, HMS (IXXAT, Beck IPC) Gateways, SystemCorp IEDs, ...
The new solutions allow to run multiple IED models (all roles) in parallel on one PC (simulating IEDs of a complete system!) ... and more. The roles and applications are configured directly by SCL files (.cid). You can build your own models and run them with all roles ... if configured.
This Package is based on our 30+ years of experience. We are really proud of offering these tools to the industry today! Sit down, enjoy and relax ...


Copyright, 2017, Michael Hüter

Click HERE to download the documentation only [pdf, 3.2 MB]
Click HERE for downloading the demo package including the documentation and license conditions.

Example: Server and Client on two PCs:


Many topologies on PCs:


... and topologies with gateways:


Click HERE to download the documentation only [pdf, 3.2 MB]
Click HERE for downloading the demo package including the documentation and license conditions.


Wednesday, April 26, 2017

NEW IEC 61850 Demo Package for Windows available

The main purpose of the new demonstration and evaluation package is to provide a free of charge simple and easy to use IEC 61850 Client/Subscriber Tool (running on Windows PCs) that can be used to communicate with a Server/Publisher implemented on the platforms:

Beck IPC DK151 Development Kit for SC145 (DK61)
Beck IPC com.tom / IXXAT SG-gateways (WEB-PLC)
SystemCorp Smart Grid Controllers
Windows PC

Several other uses cases are possible:

The demonstration uses a single generic SCL model (and a derived JSON file [JavaScript Object Notation] that can (beyond the main purpose) be used on the above platforms to automatically configure (tree structured graphical applications) for Clients, Server/Publisher, and Client/Subscriber roles as shown on the next slides.

The specification of additional models (.icd and .json) could be provided for a fee. 
Contact NettedAutomation if you are looking for other models, please.
Click HERE for further details and instructions to download the new package including the documentation.
Click HERE for documentation only.
The package is used in our training courses.

Thursday, April 13, 2017

HMS Smart Grid Gateways Are Now IXXAT SG Gateways

The HMS Smart Grid Gateways (supporting a wide range of standards like IEC 60870-5-104, IEC 61850, Modbus TCp/IP, ...) are now marketed by HMS under the HMS brand IXXAT Energy SG Gateways.
IXXAT SG-gateways... 

  • enable easy remote control and management of electrical systems
  • allow to log and display application data and energy consumption
  • provide IEC61850 client/server (publisher/subscriber) and IEC60870-5-104 client/server support
  • have in-built Modbus TCP client and Modbus RTU Master interfaces
  • provide connectivity for I/O, M-Bus, PROFIBUS, PROFINET and EtherNet/IP based devices

Click HERE for more details [EN]
Click HERE for more details [DE]